Intelligent Liquid Cooling Platform

75–600 W closed-loop liquid temperature control with integrated cooling, heating and intelligent PID control

Models and configurations

7 product entries

Cooling capacity and power consumption are listed separately as maximum values. The controller setting range is different from the equipment operating temperature range; actual liquid temperature and control performance must be confirmed against the heat load, ambient temperature and system configuration. The ±0.1°C figure is a catalogue control reference; accuracy, stability and uniformity require confirmation with the actual sensor, measuring point, load and ambient conditions. IP65 applies to the confirmed assembly; protect live terminals and assess the final equipment separately.

Need help with selection?

Share your heat load, target temperature and installation space.

Ask for Customization

Product overview

The intelligent liquid cooling platform combines cooling, heating and intelligent temperature control based on liquid cooling technology to form a closed-loop liquid temperature control system.

Closed-loop monitoring and cooling/heating switching

The intelligent controller monitors liquid temperature in real time and automatically switches between cooling and heating as ambient temperature changes, according to the difference between the measured and target temperatures, maintaining the setpoint and suppressing fluctuations under suitable operating conditions without manually switching between cooling and heating.

M-shaped channel and heat exchange

Liquid follows a spiral/multipass route through the cooling plate, where the M-shaped channel provides a larger heat exchange area for more uniform temperature distribution; during cooling, liquid is rapidly cooled through the plate and heat is removed by fan-driven convection, while during heating the intelligent controller precisely regulates the heating element.PID control uses sensor feedback; achieved performance depends on the sensor, measuring point, load and validated settings.

Precision PID adjustment

The system continuously monitors operation, with an integrated NTC thermistor measuring cooling-plate temperature in real time; abnormal temperature automatically cuts off the output and triggers an alarm, while a preset fan shutdown delay helps prevent condensation caused by temperature differences when operation pauses.

Temperature monitoring and operating protection

The digital panel displays temperature data, and RS485 communication supports data acquisition and remote control, allowing one computer to monitor and coordinate multiple devices for applications requiring high temperature stability.

Data display and remote control

The controller setting range is −40–+120°C and the platform operating range is −20–70°C; selection and actual temperature control performance must be confirmed against the heat load, ambient temperature and system configuration.

Specification comparison: 7 models

Key specifications of the seven intelligent liquid cooling platform models
ModelMaximum cooling capacityMaximum power consumptionRated VoltageStartup / steady-state currentNoise
LCP-75W-12V75 W102 W12 V DC8.5 / 7 A39 dB(A)
LCP-106W-24V106 W144 W24 V DC6 / 4.8 A43 dB(A)
LCP-150W-24V150 W204 W24 V DC6 / 4.8 A39 dB(A)
LCP-212W-48V212 W288 W48 V DC6 / 4.8 A50 dB(A)
LCP-300W-48V300 W408 W48 V DC8.5 / 7 A50 dB(A)
LCP-424W-48V424 W576 W48 V DC12 / 9.6 A53 dB(A)
LCP-600W-48V600 W816 W48 V DC17 / 14 A53 dB(A)

Standard temperature controller; Connector markings: 8 mm / PG1/8; confirm mating dimensions on the approved drawing. Equipment operating range −20~70°C; IP65 applies to the confirmed assembly. See each model for specifications and drawings.

Temperature control functions and system configuration

Intelligent liquid cooling platform with the matching digital TEC Temperature Controller

Closed-loop liquid temperature control with automatic cooling/heating switching

After a target temperature is set, the controller monitors liquid temperature in real time and determines whether cooling or heating is required. Under suitable operating conditions, the platform adjusts its output as the environment changes, maintains the liquid at the setpoint and controls fluctuations without manually switching between cooling and heating.

Cooling and heating

During cooling, liquid is rapidly cooled through the cooling plate and heat is removed by fan-driven convection; during heating, the intelligent controller precisely regulates the heating element.

M-shaped multipass channel structure in the cooling plate

M-shaped channel for thorough liquid heat exchange

Liquid follows a spiral/multipass route through the cooling plate. The M-shaped channel provides a larger heat exchange area for more uniform temperature distribution. The channel illustration explains the heat exchange structure; overall and mounting dimensions are specified in the drawing for each model.

PID control and RS485 remote communication

PID control uses sensor feedback; achieved performance depends on the sensor, measuring point, load and validated settings. The controller setting range is −40–+120°C and the platform operating range is −20–70°C.

Visible temperature data and coordinated multi-device operation

View temperature data on the digital panel. RS485 communication supports temperature data acquisition and remote control, allowing one computer to monitor and coordinate multiple devices for applications requiring high stability.

Indicator, button and terminal interface guide

Indicator markingsS/TA · C/FD · H/FD · RS485

Button markingsRET · SET · UP · DOWN

Intelligent controller terminal markings and interface descriptions
Panel markingTerminals and markingsInterface description
POWER12~48 V DC;+ / −Controller power input
TECMax.30A;+ / −TEC output terminals
FANMax.0.5A;+ / −Fan output terminals
RS485A+ / B−RS485 communication interface
NTC1 / 2Temperature probe interface
S1 / S2S1 / S2Use according to the matching controller wiring instructions

The controller's 12–48 V DC input range and the platform's rated voltage are different specifications. The matching power supply must meet the selected model's 12 V, 24 V or 48 V requirement. TEC and FAN current markings identify the respective controller terminals; they are not the complete equipment's power consumption or current. Confirm indicator meanings and the specific S1/S2 wiring against the matching controller instructions.

NTC thermistor used to monitor cooling-plate temperature

Continuous monitoring, temperature sensing and abnormal-condition protection

The platform continuously monitors operation, with an integrated NTC thermistor measuring cooling-plate temperature in real time. An abnormal temperature automatically cuts off the output and triggers an alarm to protect the equipment.

Preset fan shutdown delay

A preset fan shutdown delay helps prevent condensation caused by temperature differences after equipment operation pauses.

Contact Form

Send Your Cooling Requirement

Leave your email and any project details you already have. Our team will review the information and reply with suitable TEC / Peltier cooling options.

Name, email and phone / WhatsApp are required. Other fields are optional.

Your information will only be used for project evaluation and business communication.

Technical drawings

100%

Scroll to inspect details after zooming. Press Esc to close.

Loading drawing…