Air-to-Air Cooling Modules
212W-48V Air-to-Air TEC Cooling Module
- Maximum cooling capacity
- 212 W
- Rated Voltage
- 48 V DC
Product Series
212W-48V is a 48 V DC air-to-air assembly with 212 W catalogue maximum cooling. Its illustrated outline is 330 × 180 × 181 mm (panel width × height × total depth). Confirm the operating point, cutout and optional controller against the model drawing; maximum-capacity test conditions are not specified in the catalogue.
Technical Data & Integration
Air Cooling Modules
Air-to-air thermoelectric cooling: 7 models for different installation spaces and DC supplies.
Thermoelectric Air Cooling Modules
A compact solid-state air-to-air thermal management module for OEM equipment requiring localized cooling or enclosed-space temperature control. Separate hot-side and cold-side air circuits transfer heat without mixing the air on either side. The compressor-free, refrigerant-free design supports clean, low-noise integration with straightforward maintenance. Typical applications include medical and aesthetic equipment, laboratory instruments, analytical equipment, industrial control cabinets and other compact electronic systems. Mounting interfaces, airflow direction, DC voltage, fan configuration and control strategy can be adapted to project requirements.
No-load reference performance
For example, a 100 W air cooling module can cool an enclosed cabinet with a nominal internal volume of 15 L from 30 °C to 6 °C within 20 minutes at an ambient temperature of 30 °C, under no-load reference conditions.
Actual cooling performance varies with enclosure volume, insulation, construction, heat load, mounting method and operating conditions. Final cooling capacity and configuration must be evaluated for the actual application.
Selection notesCooling capacity and power consumption are separate quantities; both are maximum values stated in the datasheet. The datasheet does not specify the temperature difference or ambient conditions used to measure maximum cooling capacity. Model selection must therefore consider the heat load, ambient temperature, target temperature and installation conditions.
Provide your equipment heat load, ambient temperature, target temperature, available installation space and supply voltage so the model and mounting method can be checked.
View application example: cabinet coolingEnclosure Cooling CalculatorEstimate your enclosure heat load and find an air-cooling module to discuss with our engineers. Click to expandClick to collapse
Enclosure Cooling Calculator
Estimated results
- Equivalent reference capacity before derating
- Estimated TEC temperature difference
- Estimated capacity retention
Heat-load breakdown
- Enclosure walls
- Solar gain
- Air exchange
- Equipment heat
- Subtotal before margin
Indicative module selection
Estimated cooling after the assumed temperature correction
- Number of modules
- Combined catalogue maximum cooling capacity
- Estimated combined cooling at these conditions
- Combined maximum electrical power
- Rated voltage per module
The product datasheet does not specify the test conditions for its maximum cooling capacities. Module selection assumes the catalogue values can be used as the reference for this correction curve; that assumption needs verification. Our engineers must confirm performance at your actual operating conditions.
Calculation method and assumptions Click to expandClick to collapse
Six-face wall heat transfer, solar gain on the larger vertical face plus the top, ventilation sensible heat and internal equipment heat are added, then multiplied by the safety factor. Negative ambient-to-target temperature differences are set to zero for wall and ventilation loads. The total is divided by the capacity retention to obtain the equivalent reference capacity. Curve points are joined by straight lines.
- Safety factor
- 1.2
- Assumed hot-side rise above ambient
- 30 °C
- Assumed cold-side drop below target
- 8 °C
- Solar gain: light / medium / dark
- 120 / 160 / 200 W/m²
- Heat ratios: power supply / drive / servo / PLC / relay
- 10 / 5 / 10 / 50 / 20 %
- Carbon steel · U
- 5.5 W/(m²·K)
- Stainless steel · U
- 3.7 W/(m²·K)
- Powder-coated steel · U
- 5.3 W/(m²·K)
- Aluminium · U
- 6.5 W/(m²·K)
- Wood · U
- 3 W/(m²·K)
- Plastic · U
- 4 W/(m²·K)
- Glass-reinforced plastic · U
- 3 W/(m²·K)
- Foam board · U
- 0.6 W/(m²·K)
- Insulated sandwich panel · U
- 0.7 W/(m²·K)
Preliminary steady-state estimate. Humidity, condensation, door openings, cool-down time and actual electrical consumption are not calculated. Material U-values, solar gains and heat ratios are fixed estimates; enclosure construction, shading and equipment losses may differ.
Open Calculator and Sizing Guide
Specification comparison: 7 models
All models: air-to-air cooling, −20 °C to +70 °C operating temperature, IP65 and optional temperature controller. On mobile, scroll the table horizontally.
| Model | Maximum cooling capacity | Maximum power consumption | Rated voltage | Current: startup / steady | Weight | Noise | Overall dimensions / mm |
|---|---|---|---|---|---|---|---|
| 75W-12V | 75 W | 102 W | 12 V DC | 8.5 / 7 A | 1.48 kg | 39 dB(A) | 103 × 150 × 153 |
| 106W-24V | 106 W | 144 W | 24 V DC | 6 / 4.8 A | 3.68 kg | 43 dB(A) | 230 × 180 × 154 |
| 150W-24V | 150 W | 204 W | 24 V DC | 8.5 / 7 A | 2.18 kg | 39 dB(A) | 215 × 103 × 153 |
| 212W-48V | 212 W | 288 W | 48 V DC | 6 / 4.8 A | 6.18 kg | 50 dB(A) | 330 × 180 × 181 |
| 300W-48V | 300 W | 408 W | 48 V DC | 8.5 / 7 A | 7.66 kg | 50 dB(A) | 430 × 180 × 181 |
| 424W-48V | 424 W | 576 W | 48 V DC | 12 / 9.6 A | 11.69 kg | 53 dB(A) | 330 × 330 × 181 |
| 600W-48V | 600 W | 816 W | 48 V DC | 17 / 14 A | 14.48 kg | 53 dB(A) | 430 × 330 × 181 |
Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.
Model specifications and technical drawings
Expand a model to view its full specifications, overall dimensions and mounting cutout drawing. Click a drawing to open it on this page, with zoom in, zoom out and reset controls.
212W-48VMaximum cooling capacity 212 W · 48 V DC · Full specifications and dimensional drawings Click to expandClick to collapse
Product specification (English PDF)
- Cooling method
- Air-to-air
- Maximum cooling capacity
- 212 W
- Maximum power consumption
- 288 W
- Rated voltage
- 48 V DC
- Cooling current (startup / steady)
- 6 A / 4.8 A
- Temperature controller
- Optional
- Weight
- 6.18 kg
- Noise
- 50 dB(A)
- Operating temperature
- −20 °C to +70 °C
- Protection rating
- IP65
- Overall dimensions (width × height × total depth)
- 330 × 180 × 181 mm
Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.
Ask about 212W-48VConstruction, materials and protection
- Thermoelectric cooling core
- Long-life thermoelectric elements with a high temperature differential provide solid-state cooling through the Peltier effect. Cooling starts on activation and continuous operation is supported.
- SUS304 stainless steel construction
- The stainless steel construction includes the protective cover, mounting plate, fan guard and fasteners. Rounded enclosure edges help reduce the risk of scratches.
- Thick silicone rubber insulation pad
- Cushions, protects and separates the thermoelectric elements, distributes cooling more evenly and reduces thermal interaction between the hot and cold sides.
- High-fin-density aluminum alloy heat sink
- Precision CNC machining and an anodized surface support heat dissipation efficiency and service life.
- Axial fan
- High-speed, high-airflow axial fans are used; the documentation specifies 4800 RPM. The fans are the only moving parts in the cooler. See the specification table for each model’s noise level.
- Cage-clamp terminals
- Cage-clamp terminals connect the thermoelectric elements, fans and protection switch for convenient wiring.
- Overtemperature protection and warning
- A built-in snap-action thermal protection switch can output an overtemperature warning signal when excessive temperatures occur, for example following a stalled fan.
- IP65 protection
- All 7 models are specified as IP65. Live electrical terminals must still be protected from contact with liquids.
Terminal protectionThe terminals are live and must not contact liquids. The IP65 rating does not permit exposed electrical terminals to come into contact with liquids.
View material and manufacturing detailsCooling components, structural materials and electrical protection details Click to expandClick to collapse

Cooling and heat dissipation components
- Thermoelectric cooling core
- Long-life thermoelectric elements with a high temperature differential provide solid-state cooling through the Peltier effect. Cooling starts on activation and continuous operation is supported.
- Thick silicone rubber insulation pad
- Cushions, protects and separates the thermoelectric elements, distributes cooling more evenly and reduces thermal interaction between the hot and cold sides.
- High-fin-density aluminum alloy heat sink
- Precision CNC machining and an anodized surface support heat dissipation efficiency and service life.
- Axial fan
- High-speed, high-airflow axial fans are used; the documentation specifies 4800 RPM. The fans are the only moving parts in the cooler. See the specification table for each model’s noise level.

Structural and electrical protection
- SUS304 stainless steel construction
- The stainless steel construction includes the protective cover, mounting plate, fan guard and fasteners. Rounded enclosure edges help reduce the risk of scratches.
- Cage-clamp terminals
- Cage-clamp terminals connect the thermoelectric elements, fans and protection switch for convenient wiring.
- Overtemperature protection and warning
- A built-in snap-action thermal protection switch can output an overtemperature warning signal when excessive temperatures occur, for example following a stalled fan.
- IP65 protection
- All 7 models are specified as IP65. Live electrical terminals must still be protected from contact with liquids.
Technical and installation resources
Expand the cooling principle, temperature control configuration, installation requirements and wiring instructions as needed.
Cooling principle, operating characteristics and methodsCooling circuits, operating characteristics and AA / DA / LA cooling methods Click to expandClick to collapse

The cold-side heat sink and fan circulate cooled air inside an enclosed space. A separate external circuit, formed by the hot-side heat sink and fan, rejects heat to the ambient air. Suitable for localized or enclosed-space temperature control in cabinets, medical and aesthetic equipment, laboratory instruments, analytical equipment, industrial control cabinets and other compact electronic systems.
One side of a thermoelectric element cools while the other heats. Each side transfers cooling or heat to its surroundings through its own heat sink and fan: an internal cold-side circuit and an external hot-side circuit, with the two air paths kept separate.
- Operating principle
- Peltier effect, solid-state cooling
- Reliability and service life
- The cooling core has no moving parts; fans are the only moving parts in the assembly
- Temperature control accuracy
- Reference figure: ±0.1 °C, subject to confirmation for the controller configuration and operating conditions
- Vibration and shock resistance
- Solid-state cooling construction; specific vibration and shock requirements must be confirmed for each project
- Noise source
- Primarily fan noise; 39–53 dB(A) across the 7 models
- Maintenance requirements
- Simple construction with low maintenance requirements
- Environmental characteristics
- No refrigerant or compressor required
- Size and weight
- Compact cabinet integration; dimensions and weight depend on the selected model
Three cooling methods
The following describes different heat exchange interfaces. The models in this section are AA air-to-air modules; DA and LA distinguish other cooling solutions.

AA · Air-to-air
The cold-side heat sink and fan circulate cooled air within an enclosed space to reduce air temperature. All 7 products in this section use this method.

DA · Direct-to-air
A precision-machined, highly conductive aluminum cold plate sits in close contact with the equipment, cooling it through direct conductive heat transfer.

LA · Liquid-to-air
Circulating liquid flows through the cold-side heat exchanger, transferring heat through a precision-machined aluminum cold plate to cool the liquid.
Optional controller and cabinet temperature control systemTemperature control functions, optional configurations and cabinet system combinations Click to expandClick to collapse
An optional dedicated digital intelligent controller and DIN-rail switching power supply can form a cabinet environmental temperature control system. Selection, assembly, commissioning and online technical support are available. The controller supports automatic start/stop without continuous manual attendance.

- Automatic cooling/heating switchover
- Controls cooling, heating and automatic start/stop.
- Wide-range temperature control
- Controller range: −40 °C to +120 °C; accuracy: 0.1 °C.
- Two mounting options
- Independent external mounting, or a customized cooler-surface mounting configuration.
- Fault detection and alarm
- Detects faults and outputs an alarm.
- Delayed fan shutdown
- A preset delay helps reduce condensation caused by temperature differences after the cooler pauses.
- RS485 communication
- For temperature data acquisition and remote control.

Cabinet temperature control system configuration
The air cooling module, digital controller and DIN-rail switching power supply can be installed together. Confirm the supporting configuration against the equipment’s supply, installation space and temperature control requirements.
- Cooling module
- Match the model to the supply voltage
- Intelligent controller
- Temperature acquisition, cooling/heating and start/stop control
- Switching power supply
- DIN-rail mounting, selected to suit the configuration
Temperature specification notesThe controller’s control range and the module’s operating temperature are different specifications. The module’s operating temperature remains −20 °C to +70 °C. The controller range does not mean the module can operate throughout that range. Final temperature control accuracy must be confirmed for the complete system configuration and operating conditions.
Mounting methods, installation height and cutout requirementsThree mounting methods, enclosure height and model-specific cutout requirements Click to expandClick to collapse
Three mounting methods

- Through-wall mounting
- Standard version, inserted through a cutout sized for the cold side.
- Surface-mounted, projecting outward
- Mounting structure customized for the project.
- Flush-mounted, recessed inward
- Mounting structure customized for the project.

Installation height and orientation
- Confirm installation height
Installation at approximately 2/3 of the enclosure height above its base is recommended.
- Terminals facing down
Install in the illustrated orientation and check equipment and interface positions.
- Use the model-specific cutout
Insert through a cutout sized for the cold side. See each model’s mounting cutout drawing for hole positions and dimensions.
Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.
Terminal definitions and wiring logicTerminal definitions, supply wiring and overtemperature protection signal Click to expandClick to collapse

- T+
- Positive supply terminal for the Peltier elements
- T−
- Negative supply terminal for the Peltier elements
- F+
- Positive fan supply terminal
- F−
- Negative fan supply terminal
- S1 / S2
- Output terminals of the normally closed overtemperature protection switch: closed during normal operation and open on overtemperature. According to the datasheet, they may be left unconnected when the ETC80 intelligent controller is not fitted.
The diagram shows a 24 V DC supply as an example. The actual supply voltage must match the selected model.
Connect the thermoelectric elements, fans and overtemperature protection signal according to the terminal labels. The power supply and controller must match the model.
Terminal protectionThe terminals are live and must not contact liquids. The IP65 rating does not permit exposed electrical terminals to come into contact with liquids.
Product characteristics, appearance and construction may change as technology improves, without prior notice. Photography, layout and printing may cause slight differences between images and the actual product. The actual product and confirmed configuration take precedence.