Arkmex Technology custom thermoelectric cooling assembly manufacturer logo
600W-48V air-to-air thermoelectric cooling module product photograph

Air-to-Air Cooling Modules

600W-48V Air-to-Air TEC Cooling Module

Maximum cooling capacity
600 W
Rated Voltage
48 V DC

Product specification (English PDF)

Read PDFDownload PDF

Product Series

600W-48V is a 48 V DC air-to-air assembly with 600 W catalogue maximum cooling. Its illustrated outline is 430 × 330 × 181 mm (panel width × height × total depth). Confirm the operating point, cutout and optional controller against the model drawing; maximum-capacity test conditions are not specified in the catalogue.

  • Separate hot-side and cold-side air circuits
  • Compressor-free, refrigerant-free cooling
  • Customizable mounting, airflow and DC supply

Technical Data & Integration

02

Air Cooling Modules

Air-to-air thermoelectric cooling: 7 models for different installation spaces and DC supplies.

Ask about air cooling module selection

Thermoelectric Air Cooling Modules

A compact solid-state air-to-air thermal management module for OEM equipment requiring localized cooling or enclosed-space temperature control. Separate hot-side and cold-side air circuits transfer heat without mixing the air on either side. The compressor-free, refrigerant-free design supports clean, low-noise integration with straightforward maintenance. Typical applications include medical and aesthetic equipment, laboratory instruments, analytical equipment, industrial control cabinets and other compact electronic systems. Mounting interfaces, airflow direction, DC voltage, fan configuration and control strategy can be adapted to project requirements.

  • Separate hot-side and cold-side air circuits
  • Compressor-free, refrigerant-free cooling
  • Customizable mounting, airflow and DC supply
No-load reference performance

For example, a 100 W air cooling module can cool an enclosed cabinet with a nominal internal volume of 15 L from 30 °C to 6 °C within 20 minutes at an ambient temperature of 30 °C, under no-load reference conditions.

Actual cooling performance varies with enclosure volume, insulation, construction, heat load, mounting method and operating conditions. Final cooling capacity and configuration must be evaluated for the actual application.

Selection notesCooling capacity and power consumption are separate quantities; both are maximum values stated in the datasheet. The datasheet does not specify the temperature difference or ambient conditions used to measure maximum cooling capacity. Model selection must therefore consider the heat load, ambient temperature, target temperature and installation conditions.

Provide your equipment heat load, ambient temperature, target temperature, available installation space and supply voltage so the model and mounting method can be checked.

View application example: cabinet cooling
Enclosure Cooling CalculatorEstimate your enclosure heat load and find an air-cooling module to discuss with our engineers. Click to expandClick to collapse

Enclosure Cooling Calculator

1 · Enclosure

U = 5.5 W/(m²·K)

2 · Environment
3 · Internal heat

Enter heat dissipated inside the enclosure, rather than the equipment's rated electrical power. Enter 0 if there is no internal heat source.

Estimated results

Enter the enclosure dimensions, temperatures and heat-load data to calculate.

The product datasheet does not specify the test conditions for its maximum cooling capacities. Module selection assumes the catalogue values can be used as the reference for this correction curve; that assumption needs verification. Our engineers must confirm performance at your actual operating conditions.

Calculation method and assumptions Click to expandClick to collapse

Six-face wall heat transfer, solar gain on the larger vertical face plus the top, ventilation sensible heat and internal equipment heat are added, then multiplied by the safety factor. Negative ambient-to-target temperature differences are set to zero for wall and ventilation loads. The total is divided by the capacity retention to obtain the equivalent reference capacity. Curve points are joined by straight lines.

Safety factor
1.2
Assumed hot-side rise above ambient
30 °C
Assumed cold-side drop below target
8 °C
Solar gain: light / medium / dark
120 / 160 / 200 W/m²
Heat ratios: power supply / drive / servo / PLC / relay
10 / 5 / 10 / 50 / 20 %
Carbon steel · U
5.5 W/(m²·K)
Stainless steel · U
3.7 W/(m²·K)
Powder-coated steel · U
5.3 W/(m²·K)
Aluminium · U
6.5 W/(m²·K)
Wood · U
3 W/(m²·K)
Plastic · U
4 W/(m²·K)
Glass-reinforced plastic · U
3 W/(m²·K)
Foam board · U
0.6 W/(m²·K)
Insulated sandwich panel · U
0.7 W/(m²·K)

Preliminary steady-state estimate. Humidity, condensation, door openings, cool-down time and actual electrical consumption are not calculated. Material U-values, solar gains and heat ratios are fixed estimates; enclosure construction, shading and equipment losses may differ.

Open Calculator and Sizing Guide

Specification comparison: 7 models

All models: air-to-air cooling, −20 °C to +70 °C operating temperature, IP65 and optional temperature controller. On mobile, scroll the table horizontally.

Maximum cooling capacity, maximum power consumption, voltage, current, weight, noise and overall dimensions of 7 air cooling modules
ModelMaximum cooling capacityMaximum power consumptionRated voltageCurrent: startup / steadyWeightNoiseOverall dimensions / mm
75W-12V 75 W102 W12 V DC 8.5 / 7 A1.48 kg39 dB(A)103 × 150 × 153
106W-24V 106 W144 W24 V DC 6 / 4.8 A3.68 kg43 dB(A)230 × 180 × 154
150W-24V 150 W204 W24 V DC 8.5 / 7 A2.18 kg39 dB(A)215 × 103 × 153
212W-48V 212 W288 W48 V DC 6 / 4.8 A6.18 kg50 dB(A)330 × 180 × 181
300W-48V 300 W408 W48 V DC 8.5 / 7 A7.66 kg50 dB(A)430 × 180 × 181
424W-48V 424 W576 W48 V DC 12 / 9.6 A11.69 kg53 dB(A)330 × 330 × 181
600W-48V 600 W816 W48 V DC 17 / 14 A14.48 kg53 dB(A)430 × 330 × 181

Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.

Model specifications and technical drawings

Expand a model to view its full specifications, overall dimensions and mounting cutout drawing. Click a drawing to open it on this page, with zoom in, zoom out and reset controls.

600W-48VMaximum cooling capacity 600 W · 48 V DC · Full specifications and dimensional drawings Click to expandClick to collapse

Product specification (English PDF)

Cooling method
Air-to-air
Maximum cooling capacity
600 W
Maximum power consumption
816 W
Rated voltage
48 V DC
Cooling current (startup / steady)
17 A / 14 A
Temperature controller
Optional
Weight
14.48 kg
Noise
53 dB(A)
Operating temperature
−20 °C to +70 °C
Protection rating
IP65
Overall dimensions (width × height × total depth)
430 × 330 × 181 mm
Overall dimensions
Mounting cutout dimensions

Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.

Ask about 600W-48V

Construction, materials and protection

Exploded view of an air cooling module: axial fan, stainless steel enclosure, terminals, aluminum alloy heat sink, silicone rubber insulation pad, thermoelectric elements and overtemperature protection switch
Hot/cold-side separation and main structural components
Thermoelectric cooling core
Long-life thermoelectric elements with a high temperature differential provide solid-state cooling through the Peltier effect. Cooling starts on activation and continuous operation is supported.
SUS304 stainless steel construction
The stainless steel construction includes the protective cover, mounting plate, fan guard and fasteners. Rounded enclosure edges help reduce the risk of scratches.
Thick silicone rubber insulation pad
Cushions, protects and separates the thermoelectric elements, distributes cooling more evenly and reduces thermal interaction between the hot and cold sides.
High-fin-density aluminum alloy heat sink
Precision CNC machining and an anodized surface support heat dissipation efficiency and service life.
Axial fan
High-speed, high-airflow axial fans are used; the documentation specifies 4800 RPM. The fans are the only moving parts in the cooler. See the specification table for each model’s noise level.
Cage-clamp terminals
Cage-clamp terminals connect the thermoelectric elements, fans and protection switch for convenient wiring.
Overtemperature protection and warning
A built-in snap-action thermal protection switch can output an overtemperature warning signal when excessive temperatures occur, for example following a stalled fan.
IP65 protection
All 7 models are specified as IP65. Live electrical terminals must still be protected from contact with liquids.

Terminal protectionThe terminals are live and must not contact liquids. The IP65 rating does not permit exposed electrical terminals to come into contact with liquids.

View material and manufacturing detailsCooling components, structural materials and electrical protection details Click to expandClick to collapse
Illustrative manufacturing details of thermoelectric elements, axial fan, high-fin-density aluminum alloy heat sink and silicone rubber insulation pad
Illustrative materials and construction; the approved drawings and actual product determine the final configuration.
Cooling and heat dissipation components
Thermoelectric cooling core
Long-life thermoelectric elements with a high temperature differential provide solid-state cooling through the Peltier effect. Cooling starts on activation and continuous operation is supported.
Thick silicone rubber insulation pad
Cushions, protects and separates the thermoelectric elements, distributes cooling more evenly and reduces thermal interaction between the hot and cold sides.
High-fin-density aluminum alloy heat sink
Precision CNC machining and an anodized surface support heat dissipation efficiency and service life.
Axial fan
High-speed, high-airflow axial fans are used; the documentation specifies 4800 RPM. The fans are the only moving parts in the cooler. See the specification table for each model’s noise level.
Illustrative material and manufacturing details of a rounded stainless steel enclosure, cage-clamp terminals and thermal protection switch
Illustrative materials and construction; the approved drawings and actual product determine the final configuration.
Structural and electrical protection
SUS304 stainless steel construction
The stainless steel construction includes the protective cover, mounting plate, fan guard and fasteners. Rounded enclosure edges help reduce the risk of scratches.
Cage-clamp terminals
Cage-clamp terminals connect the thermoelectric elements, fans and protection switch for convenient wiring.
Overtemperature protection and warning
A built-in snap-action thermal protection switch can output an overtemperature warning signal when excessive temperatures occur, for example following a stalled fan.
IP65 protection
All 7 models are specified as IP65. Live electrical terminals must still be protected from contact with liquids.

Technical and installation resources

Expand the cooling principle, temperature control configuration, installation requirements and wiring instructions as needed.

Cooling principle, operating characteristics and methodsCooling circuits, operating characteristics and AA / DA / LA cooling methods Click to expandClick to collapse
Separate air circuits for cooled-air circulation inside a cabinet and heat rejection outside it
Cooling by internal convection in an enclosed space

The cold-side heat sink and fan circulate cooled air inside an enclosed space. A separate external circuit, formed by the hot-side heat sink and fan, rejects heat to the ambient air. Suitable for localized or enclosed-space temperature control in cabinets, medical and aesthetic equipment, laboratory instruments, analytical equipment, industrial control cabinets and other compact electronic systems.

One side of a thermoelectric element cools while the other heats. Each side transfers cooling or heat to its surroundings through its own heat sink and fan: an internal cold-side circuit and an external hot-side circuit, with the two air paths kept separate.

Operating principle
Peltier effect, solid-state cooling
Reliability and service life
The cooling core has no moving parts; fans are the only moving parts in the assembly
Temperature control accuracy
Reference figure: ±0.1 °C, subject to confirmation for the controller configuration and operating conditions
Vibration and shock resistance
Solid-state cooling construction; specific vibration and shock requirements must be confirmed for each project
Noise source
Primarily fan noise; 39–53 dB(A) across the 7 models
Maintenance requirements
Simple construction with low maintenance requirements
Environmental characteristics
No refrigerant or compressor required
Size and weight
Compact cabinet integration; dimensions and weight depend on the selected model
Three cooling methods

The following describes different heat exchange interfaces. The models in this section are AA air-to-air modules; DA and LA distinguish other cooling solutions.

AA Air-to-air cooling assembly illustration
AA · Air-to-air

The cold-side heat sink and fan circulate cooled air within an enclosed space to reduce air temperature. All 7 products in this section use this method.

DA Direct-to-air cooling assembly illustration
DA · Direct-to-air

A precision-machined, highly conductive aluminum cold plate sits in close contact with the equipment, cooling it through direct conductive heat transfer.

LA Liquid-to-air cooling assembly illustration
LA · Liquid-to-air

Circulating liquid flows through the cold-side heat exchanger, transferring heat through a precision-machined aluminum cold plate to cool the liquid.

Optional controller and cabinet temperature control systemTemperature control functions, optional configurations and cabinet system combinations Click to expandClick to collapse

An optional dedicated digital intelligent controller and DIN-rail switching power supply can form a cabinet environmental temperature control system. Selection, assembly, commissioning and online technical support are available. The controller supports automatic start/stop without continuous manual attendance.

Example TEC Temperature Controller digital controller, showing a range of −40 °C to +120 °C and 0.1 °C accuracy
Intelligent controller, optional.
Automatic cooling/heating switchover
Controls cooling, heating and automatic start/stop.
Wide-range temperature control
Controller range: −40 °C to +120 °C; accuracy: 0.1 °C.
Two mounting options
Independent external mounting, or a customized cooler-surface mounting configuration.
Fault detection and alarm
Detects faults and outputs an alarm.
Delayed fan shutdown
A preset delay helps reduce condensation caused by temperature differences after the cooler pauses.
RS485 communication
For temperature data acquisition and remote control.
Installation example of an air cooling module, digital controller and DIN-rail switching power supply inside a cabinet
Cabinet temperature control system configuration

The air cooling module, digital controller and DIN-rail switching power supply can be installed together. Confirm the supporting configuration against the equipment’s supply, installation space and temperature control requirements.

Cooling module
Match the model to the supply voltage
Intelligent controller
Temperature acquisition, cooling/heating and start/stop control
Switching power supply
DIN-rail mounting, selected to suit the configuration

Temperature specification notesThe controller’s control range and the module’s operating temperature are different specifications. The module’s operating temperature remains −20 °C to +70 °C. The controller range does not mean the module can operate throughout that range. Final temperature control accuracy must be confirmed for the complete system configuration and operating conditions.

Mounting methods, installation height and cutout requirementsThree mounting methods, enclosure height and model-specific cutout requirements Click to expandClick to collapse
Three mounting methods
From left: through-wall mounting, outward-projecting surface mounting and inward-recessed flush mounting
Through-wall mounting
Standard version, inserted through a cutout sized for the cold side.
Surface-mounted, projecting outward
Mounting structure customized for the project.
Flush-mounted, recessed inward
Mounting structure customized for the project.
Recessed installation of an air cooling module at approximately two-thirds of the enclosure height, with terminals facing down
Installation height and orientation
  1. Confirm installation height

    Installation at approximately 2/3 of the enclosure height above its base is recommended.

  2. Terminals facing down

    Install in the illustrated orientation and check equipment and interface positions.

  3. Use the model-specific cutout

    Insert through a cutout sized for the cold side. See each model’s mounting cutout drawing for hole positions and dimensions.

View model-specific cutout drawings

Dimensions are in mm. Measurements were taken manually and may vary; refer to the actual product and approved drawings. Overall dimensions are listed as the illustrated panel width × height × total depth.

Terminal definitions and wiring logicTerminal definitions, supply wiring and overtemperature protection signal Click to expandClick to collapse
Six-position cage-clamp terminal block, labeled T+, T−, F+, F−, S1 and S2 in sequence
Thermoelectric element supply, fan supply and overtemperature protection output terminals
T+
Positive supply terminal for the Peltier elements
T−
Negative supply terminal for the Peltier elements
F+
Positive fan supply terminal
F−
Negative fan supply terminal
S1 / S2
Output terminals of the normally closed overtemperature protection switch: closed during normal operation and open on overtemperature. According to the datasheet, they may be left unconnected when the ETC80 intelligent controller is not fitted.
Direct power supply wiring diagram

The diagram shows a 24 V DC supply as an example. The actual supply voltage must match the selected model.

Cooler + controller + power supply wiring diagram

Connect the thermoelectric elements, fans and overtemperature protection signal according to the terminal labels. The power supply and controller must match the model.

Terminal protectionThe terminals are live and must not contact liquids. The IP65 rating does not permit exposed electrical terminals to come into contact with liquids.

Product characteristics, appearance and construction may change as technology improves, without prior notice. Photography, layout and printing may cause slight differences between images and the actual product. The actual product and confirmed configuration take precedence.

Contact Form

Send Your Cooling Requirement

Leave your email and any project details you already have. Our team will review the information and reply with suitable TEC / Peltier cooling options.

Name, email and phone / WhatsApp are required. Other fields are optional.

Your information will only be used for project evaluation and business communication.

Technical drawings

100%

Scroll to inspect details after zooming. Press Esc to close.

Loading drawing…