LCP-300W-48V

LCP-300W-48V Intelligent Liquid Cooling Platform

Maximum cooling capacity
300 W
Maximum power consumption
408 W
Rated Voltage
48 V DC
Cooling method
Liquid to air

Product overview

The intelligent liquid cooling platform combines cooling, heating and intelligent temperature control based on liquid cooling technology to form a closed-loop liquid temperature control system.

Closed-loop monitoring and cooling/heating switching

The intelligent controller monitors liquid temperature in real time and automatically switches between cooling and heating as ambient temperature changes, according to the difference between the measured and target temperatures, maintaining the setpoint and suppressing fluctuations under suitable operating conditions without manually switching between cooling and heating.

M-shaped channel and heat exchange

Liquid follows a spiral/multipass route through the cooling plate, where the M-shaped channel provides a larger heat exchange area for more uniform temperature distribution; during cooling, liquid is rapidly cooled through the plate and heat is removed by fan-driven convection, while during heating the intelligent controller precisely regulates the heating element.PID control uses sensor feedback; achieved performance depends on the sensor, measuring point, load and validated settings.

Precision PID adjustment

The system continuously monitors operation, with an integrated NTC thermistor measuring cooling-plate temperature in real time; abnormal temperature automatically cuts off the output and triggers an alarm, while a preset fan shutdown delay helps prevent condensation caused by temperature differences when operation pauses.

Temperature monitoring and operating protection

The digital panel displays temperature data, and RS485 communication supports data acquisition and remote control, allowing one computer to monitor and coordinate multiple devices for applications requiring high temperature stability.

Data display and remote control

The controller setting range is −40–+120°C and the platform operating range is −20–70°C; selection and actual temperature control performance must be confirmed against the heat load, ambient temperature and system configuration.

  • Automatic bidirectional switching between cooling and heating
  • PID feedback temperature control
  • NTC temperature monitoring and fault alarms
  • RS485 data acquisition and remote control

Technical specifications

LCP-300W-48V complete product specifications
ParameterValue
ModelLCP-300W-48V
Cooling methodLiquid to air
Maximum cooling capacity300 W
Maximum power consumption408 W
Rated Voltage48 V DC
Cooling currentStartup 8.5 A / Steady-state 7 A
Temperature controllerIncluded as standard
Connection dimensionsConnector markings: 8 mm / PG1/8; confirm mating dimensions on the approved drawing
Noise50 dB(A)
Operating temperature−20~70°C
Ingress protectionIP65

Cooling capacity and power consumption are listed separately as maximum values. The controller setting range is different from the equipment operating temperature range; actual liquid temperature and control performance must be confirmed against the heat load, ambient temperature and system configuration. The ±0.1°C figure is a catalogue control reference; accuracy, stability and uniformity require confirmation with the actual sensor, measuring point, load and ambient conditions. IP65 applies to the confirmed assembly; protect live terminals and assess the final equipment separately.

Overall dimensions and mounting drawings

Download complete dimensional drawing

Dimensions in mm. Views retain their proportions; use the annotated dimensions. Check mounting holes, connection positions and clearance.

Top view

Side view

End view

Temperature control functions and system configuration

Intelligent liquid cooling platform with the matching digital TEC Temperature Controller

Closed-loop liquid temperature control with automatic cooling/heating switching

After a target temperature is set, the controller monitors liquid temperature in real time and determines whether cooling or heating is required. Under suitable operating conditions, the platform adjusts its output as the environment changes, maintains the liquid at the setpoint and controls fluctuations without manually switching between cooling and heating.

Cooling and heating

During cooling, liquid is rapidly cooled through the cooling plate and heat is removed by fan-driven convection; during heating, the intelligent controller precisely regulates the heating element.

M-shaped multipass channel structure in the cooling plate

M-shaped channel for thorough liquid heat exchange

Liquid follows a spiral/multipass route through the cooling plate. The M-shaped channel provides a larger heat exchange area for more uniform temperature distribution. The channel illustration explains the heat exchange structure; overall and mounting dimensions are specified in the drawing for each model.

PID control and RS485 remote communication

PID control uses sensor feedback; achieved performance depends on the sensor, measuring point, load and validated settings. The controller setting range is −40–+120°C and the platform operating range is −20–70°C.

Visible temperature data and coordinated multi-device operation

View temperature data on the digital panel. RS485 communication supports temperature data acquisition and remote control, allowing one computer to monitor and coordinate multiple devices for applications requiring high stability.

Indicator, button and terminal interface guide

Indicator markingsS/TA · C/FD · H/FD · RS485

Button markingsRET · SET · UP · DOWN

Intelligent controller terminal markings and interface descriptions
Panel markingTerminals and markingsInterface description
POWER12~48 V DC;+ / −Controller power input
TECMax.30A;+ / −TEC output terminals
FANMax.0.5A;+ / −Fan output terminals
RS485A+ / B−RS485 communication interface
NTC1 / 2Temperature probe interface
S1 / S2S1 / S2Use according to the matching controller wiring instructions

The controller's 12–48 V DC input range and the platform's rated voltage are different specifications. The matching power supply must meet the selected model's 12 V, 24 V or 48 V requirement. TEC and FAN current markings identify the respective controller terminals; they are not the complete equipment's power consumption or current. Confirm indicator meanings and the specific S1/S2 wiring against the matching controller instructions.

NTC thermistor used to monitor cooling-plate temperature

Continuous monitoring, temperature sensing and abnormal-condition protection

The platform continuously monitors operation, with an integrated NTC thermistor measuring cooling-plate temperature in real time. An abnormal temperature automatically cuts off the output and triggers an alarm to protect the equipment.

Preset fan shutdown delay

A preset fan shutdown delay helps prevent condensation caused by temperature differences after equipment operation pauses.

Contact Form

Send Your Cooling Requirement

Leave your email and any project details you already have. Our team will review the information and reply with suitable TEC / Peltier cooling options.

Name, email and phone / WhatsApp are required. Other fields are optional.

Your information will only be used for project evaluation and business communication.

Technical drawings

100%

Scroll to inspect details after zooming. Press Esc to close.

Loading drawing…